BJKXV - FAULT-FINDER CLEANER 1031

Product Identification

Product ID:FAULT-FINDER CLEANER 1031
MSDS Date:04/07/1986
FSC:6850
NIIN:00-782-2740
MSDS Number: BJKXV

Responsible Party
CROWN INDUSTRIAL PRODUCTS CO., INC
STATE LINE ROAD
HEBRON, IL 60034
US

Emergency Phone: 815-648-2424

Info Phone: 815-648-2424

Preparer: GREGORY GLAD

Cage: 92381

Contractor
CROWN INDUSTRIAL PRODUCTS CO
350 HEBRON, IL 60034 US

Telephone: 815-648-2424

Cage: 92381

Ingredients

SOLVENT NAPHTHA (PETROLEUM) ALIPHATIC LIGHT

CAS: 64742-89-8

Fraction By Weight: 70.0%

OSHA PEL 300PPM/STEL 400PPM

ACGIH TLV: 300PPM/STEL 400PPM


LIQUIFIED PETROLEUM GAS, SWEETENED (11-30%) THIS IS MIXTURE

CAS: 68476-86-8

Fraction By Weight: 11-30%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE IRRITATION TO NOSE, THROAT,
RESPIRATORY TRACT, EYES, AND SKIN.
Effects of Overexposure:INHALATION: MAY BE IRRITATING TO NOSE, THROAT,
AND RESPIRATORY TRACT. HIGH CONCENTRATION MAY RESULT IN CNS
DEPRESSION. INGESTION: MAY RESULT IN VOMITING. EYES: CAUSES MILD
IRRITATION. SKIN: MILD IRRI TATING. PROLONGED EXPOSURE CAN RESULT
IN DEFATTING AND DRYING OF SKIN, WHICH CAN RESULT IN DERMATITIS.
Medical Cond Aggravated by Exposure:PREEXISTING EYE, SKIN AND
RESPIRATORY DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO THIS
PRODUCT.

First Aid

First Aid:INGESTION: DO NOT INDUCE VOMITING.IF VOMITING OCCURS
SPONTANEOUSLY, KEEP HEAD BELOW HIPS TO PREVENT ASPIRATION OF LIQUID
INTO THE LUNGS. CALL A DOCTOR. DO NOT GIVE EPINEPHRINE OR SIMILAR
DRUGS. INHALA TION: REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING
IS DIFFICULT. GIVE ARTIFICIAL RESPIRATION IF NOT BREATHING. EYES:
WASH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. SKIN: WASH WITH
SOAP AND WATER.

Fire Fighting

Flash Point:N/R (AEROSOL CAN
Lower Limits:1.8
Upper Limits:9.5
Extinguishing Media:WATER FOG, DRY CHEMICAL, FOAM, CARBON DIOXIDE
Fire Fighting Procedures:COOL EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:AEROSOPL CANS WILL EXPLODE IN HEAT OF
FIRE. TREAT AS CYLINDER OF COMPRESSED GAS. FACE SHIELDS, HELMETS
AND SELF CONTAINED BREATHING APPARATUS IS RECOMMENDED.

Accidental Release

Spill Release Procedures:IF LIQUID SPILLS OUT, VENTILATE AREA. REMOVE
ALL SOURCES OF IGNITION. CLEAN UP WITH INERT MATERIALS. SEGREGATE
AND REMOVE THE LEAKING AEROSOL CANS.

Handling

Handling and Storage Precautions:DO NOT STORE IN DIRECT SUNLIGHT OR
WHERE TEMPERATURE EXCEED 120F. AVOID SPLASH FILLING, OPEN FLAME,
SPARKS. USE IN WELL-VENTILATED AREA.
Other Precautions:DO NOT SPRAY ON FLAMES, HOT SURFACES. AVOID
INHALATION OF VAPORS. AVOID PHYSICAL DAMAGE TO THE CONTAINERS.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR TO PREVENT
OVER-EXPOSURE IN ACCORDANCE WITH 29CFR1910.134
Ventilation:MECHANICAL - EXPLOSION PROOF RECOMMENDED.LOCAL - YES
Protective Gloves:BEST - NITRILE OR POLYVINYL ALCOHOL.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:NONE
Work Hygienic Practices:AIR DRY CONTAMINATED CLOTHING AND LAUNDER
BEFORE RE-USE.
Supplemental Safety and Health
THIS PRODUCT FAULT FINDER CLEANER 1031 IS ONE OF THREE PARTS KIT. THIS
ENTRY REPRESENTS NEW FORMULATION OF 1031. THE OLD 1031 CLEANER IS
UNDER PNI 'A' THIS NSN. OTHER PARTS OF THE KIT ARE: PENETRANT 1 032
AND DEVELOPER 1033. PREVIOUSLY THESE ITEMS WERE OF GROUP VII. PER
QPL NOW ARE TYPE I,METHOD C,LEVEL 3; KEY1:F1

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:240-270F
Vapor Pres:2224MMHG
Vapor Density:5.8
Spec Gravity:0.75
Evaporation Rate & Reference:1.2 (BU-ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUID, LIGHT PETROLEUM ODOR BEFORE
FILLING IN AEROSOL CANS.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:OPEN FLAMES OR SPARK SOURCES
Hazardous Decomposition Products:CARBON MONOXIDE,CARBON DIOXIDE

Disposal

Waste Disposal Methods:AEROSOL CONTAINER: DO NOT PUNCTURE OR
INCINERATE. EMPTY CONTAINERS MAY BE DISPOSED OF THROUGH NORMAL
CHANNELS. FULL OR PARTIALLY FILLED CONTAINERS ARE CONSIDERED
HAZARDOUS WASTE. COMPLY WITH ALL FEDER AL, STATE, LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.